Fonte: http://www.tequipment.net/Fluke_TL-VoltageProbes.html
Fonte: http://produto.mercadolivre.com.br/MLB-477765812-pontas-de-prova-para-osciloscopio-fluke-vp-100-100mhz-_JM
Fonte: http://www.ebay.com/itm/NEW-FLUKE-Oscilloscope-Voltage-Probe-Set-/261213826427
Fonte: http://www.amazon.com/100MHz-Oscilloscope-Clip-Probes-Accessory/dp/B0030KWM30/ref=pd_rhf_ee_s_cp_3_4TZW
Fonte: ebay
Pontas de provas e acessórios para o Fluke 99 Series II.
Fluke Voltage Probes
Voltage Probes Back to Top | ||||||||
Model | AC Probes Description or Specification | Buy Now | ||||||
Fluke VPS210-R | Fluke VPS210-R - Voltage Probe Set 200 MHz, Red, (one, red) |
| ||||||
Fluke VPS210-G | Fluke VPS210-G - Voltage Probe Set GREY, 200 MHZ, 1.2M |
|
Discontinued Back to Top | ||
Description or Specification | ||
Fluke VPS100 | Discontinued Replaced by Fluke VPS210-R | |
Fluke VPS100-R | Discontinued Replaced by Fluke VPS210-R | |
Fluke VPS121 | Discontinued No Replacement | |
Fluke VPS201 | Discontinued No Replacement | |
Fluke VPS250 | Discontinued No Replacement | |
Fluke VP190-G | Discontinued Replaced by Fluke VPS210-G | |
Fluke VP190-R | Discontinued Replaced by Fluke VPS210-R | |
Fluke VPS200-G | Discontinued Replaced by Fluke VPS210-G | |
Fluke VPS200-R | Discontinued Replaced by Fluke VPS210-R | |
Fluke VPS40 | Discontinued Replaced by Fluke VPS40-III |
PM8918 probe series
Model
Description
Replacement
PM8918/301 Current
Low Pass Filter Probe One blue 10:1 2.5m
PM8918/001Obsolete
10:1 Probe Set Red
PM8918/002Obsolete
10:1 Probe Set Red & Gray
PM8918/003Obsolete
10:1 Probe Set Gray
PM8918/101Obsolete
1:1 Probe Set Black
PM8918/202Obsolete
10:1 2.5m. Probe Set
PM8918/301 10:1 Low Pass Filter Probe 4 kHz
Low Pass Filter Probe Probe includes:
- 600 V CAT III rated 10:1 Probe, One blue
- Probe tip to banana adapter
- High voltage test-pin
- 42 Vpk/30 Vrms rated mini Test-hook
Probe Length: 2.5m
Maximum Signal Voltage: 600 V
Maximum Voltage to Ground: 600 V rms. CAT III per IEC 1010-2-031
Attenuation: 10x
Bandwidth: 4 kHz
Input Resistance: 10 Mohm
Input Capacitance: 12.5 pF
Compensation Range: 15 to 35 pF
Note: When using the mini Test-hooks any potential must not exceed 42V pk/30 Vrms
BB120 Shielded Banana to BNC Adapter is required to adapt to ScopeMeter 120 Series shielded banana jack inputs.
PM8918/001 One red
PM8918/002 One red and one gray
PM8918/003 One gray
10:1 Safety Designed Probes
Probes include 600V CAT III rated 10:1 Probe, Probe tip to banana adapter, High voltage test-pin, and 42Vpk/30Vrms rated HF adapter and mini Test-hook.Probe Length: 1.5m (5 ft.)
Maximum Signal Voltage: 600Vrms CAT III , per IEC 1010-2-031
Maximum Voltage to Ground: 600Vrms CAT III , per IEC 1010-2-031
Attenuation: 10x
Bandwidth: 100MHz
Input Resistance: 10Mohm
Input Capacitance: 15pF
Compensation Range: 15 …35 pF
Note: When using the HF adapters or mini Test-hooks any potential must not exceed 42Vpk/30Vrms
BB120 Shielded Banana to BNC Adapter is required to adapt to ScopeMeter 120 Series shielded banana jack inputs.
VPS100 Voltage Probe Set 100 MHz (red & gray)
For ScopeMeter 90 Series, replaces PM8918 probe series.
Double insulated safety designed probe.
Each probe set includes 600 V CAT III / 1000 V CAT II rated
10:1 Voltage Probe (1 red, 1 gray)
Hook Clip for Probe Tip (1 red, 1 gray)
4-mm Test Probe for Probe (1 red, 1 gray)
Ground Lead with Hook Clip (1 red, 1 gray)
Ground Lead with Mini Alligator (2 black)
30V CAT II rated Ground
Spring for Probe Tip (1x)
Attenuation: 10x
Bandwidth: 100 MHz
Max. Input Voltage: 1000 V
Max. Voltage to ground: 600 V CAT III, 1000 V CAT II per IEC / EN61010-031
Input Resistance: 10 Mohm
Input Capacitance: 16 pF
Compensation range: 10 to 35 pF
Cable Length: 1.2 m
BB120 Shielded Banana to BNC Adapter is required to adapt to ScopeMeter 120 Series shielded banana jack inputs.
VPS100-R 10:1 Voltage Probe Red 100 MHz (one red)
For ScopeMeter 90 Series, replaces PM8918 probe series.
Double insulated safety designed probe.
Probe set includes includes 600 V CAT III / 1000 V CAT II rated
10:1 Voltage Probe (1 red)
Hook Clip for Probe Tip (1 red)
4-mm Test Probe for Probe (1 red)
Ground Lead with Hook Clip (1 red)
Ground Lead with Mini Alligator (1 black)
30V CAT II rated Ground Spring for Probe Tip (1x)
Attenuation: 10x
Bandwidth: 100 MHz
Max. Input Voltage: 1000V
Max. Voltage to ground: 600V CAT III, 1000V CAT II per IEC / EN61010-031
Input Resistance: 10 Mohm
Input Capacitance: 16 pF
Compensation range: 10 to 35 pF
Cable Length: 1.2 m
BB120 Shielded Banana to BNC Adapter is required to adapt to ScopeMeter 120 Series shielded banana jack inputs.
PM8918/101 1:1 Probe Set Black
Obsolete. Replacement is VPS121
Includes 300V CAT III rated 1:1 Probe, Probe tip to banana adapter, High voltage test-pin, and 42Vpk/30Vrms rated mini Test-hook.
Probe Length: 1.5m (5 ft.)
Maximum Signal Voltage: 300Vrms CAT III , per IEC 1010-2-031
Maximum Voltage to Ground: 600Vrms CAT III , per IEC 1010-2-031
Attenuation: 1x
Bandwidth: 12MHz
Input Resistance: 1Mohm
Input Capacitance: <60pF
Note: When using the mini Test-hook any potential must not exceed 42Vpk/30Vrms
BB120 Shielded Banana to BNC Adapter is required to adapt to ScopeMeter 120 Series shielded banana jack inputs.
VPS121 1:1 Voltage Probe Set 12 MHz (one black)
Double insulated safety designed probe.
Each probe set includes 300 V CAT III
1:1 Voltage Probe (1 black)
Hook Clip for Probe Tip (1 red)
4-mm Test Probe for Probe (1 red)
Ground Lead with Hook Clip (1 red)
Ground Lead with Mini Alligator (1 black)
Attenuation: 1x
Bandwidth: 12 MHz
Max. Input Voltage: 300 V
Max. Voltage to ground: 600 V CAT III rated per IEC / EN61010-031
Input Resistance: 1 Mohm
Input Capacitance: 42 pF +Oscilloscope Input Capacitance
Cable Length: 1.2 m
BB120 Shielded Banana to BNC Adapter is required to adapt to ScopeMeter 120 Series shielded banana jack inputs.
PM8918/202 10:1, 2.5m. Probe Set. One red and one gray
Obsolete. Replacement is VPS250
Probes include 600V CAT III rated 10:1 Probe, Probe tip to banana adapter, High Voltage test-pin, and 42Vpk/30Vrms rated HF adapter and mini Test-hook.
Probe Length: 2.5m (8 ft.)
Maximum Signal Voltage: 600Vrms CAT III , per IEC 1010-2-031
Maximum Voltage to Ground: 600Vrms CAT III , per IEC 1010-2-031
Attenuation: 10x
Bandwidth: 75MHz
Input Resistance: 10Mohm
Input Capacitance: 15pF
Compensation Range: 15 …35 pF
Note: When using the HF adapters or mini Test-hooks any potential must not exceed 42Vpk/30Vrms
BB120 Shielded Banana to BNC Adapter is required to adapt to ScopeMeter 120 Series shielded banana jack inputs.
VPS250 2.5m Voltage Probe Set 75 MHz (red & gray)
Double insulated safety designed probe.
Each probe set includes
600 V CAT III / 1000V CAT II rated
10:1 Voltage Probe (1 red, 1 gray)
Hook Clip for Probe Tip (1 red, 1 gray)
4 mm Test Probe for Probe (1 red, 1 gray)
Ground Lead with Hook Clip (1 red, 1gray)
Ground Lead with Mini Alligator (2 black)
Attenuation: 10x
Bandwidth: 75 MHz
Max. Input Voltage: 1000 V
Max. Voltage to ground: 600 V CAT III, 1000 V CAT II per IEC / EN61010-031
Input Resistance: 10 MOhm
Input Capacitance: 18.5 pF
Compensation range: 10 to 35 pF
Cable Length: 2.5m
BB120 Shielded Banana to BNC Adapter is required to adapt to ScopeMeter 120 Series shielded banana jack inputs.
PM9084/001 Alligator clip for PM8918 Probe
Safety-designed, spring-loaded alligator clips with a 19 mm (0.75") jaw opening for use with PM 8918 safety designed probes. Set contains one red and one gray clip.
Maximum Voltage: 600V rms. CAT III , per IEC 1010-2-031
PM9085/001 Probe Hook-Style Clip for PM8918 Probe
Obsolete. Replacement is RS200
Safety-designed spring-loaded hook clip for use with PM 8918 safety designed probes.
Hook extends 10 mm x 2 mm (0.39" x 0.07").
Set contains one red and one gray clip.
Maximum Voltage: 600V rms. CAT III , per IEC 1010-2-031
PM9094/001 Probe accessory Set for PM8918 series probes
Set consists of:
1 Adapter Banana-BNC (PM 9081/001)
2 Probe tips to Banana Adapters, 1 red, 1 gray
2 HF Adapters, black, max voltage 30V rms.
2 Mini Testhooks, 1 red, 1 gray, max voltage 30V rms.
2 Trim Screwdrivers, 1 red, 1 gray
2 High Voltage Testpins, 1 red, 1 gray
Note: When using the mini Test-hooks any potential must not exceed 42Vpk/30Vrms
Model
|
Description
|
Replacement
|
PM8918/301 Current
|
Low Pass Filter Probe One blue 10:1 2.5m
| |
PM8918/001Obsolete
|
10:1 Probe Set Red
| |
PM8918/002Obsolete
|
10:1 Probe Set Red & Gray
| |
PM8918/003Obsolete
|
10:1 Probe Set Gray
| |
PM8918/101Obsolete
|
1:1 Probe Set Black
| |
PM8918/202Obsolete
|
10:1 2.5m. Probe Set
|
PM8918/301 10:1 Low Pass Filter Probe 4 kHz
Low Pass Filter Probe Probe includes:
- 600 V CAT III rated 10:1 Probe, One blue
- Probe tip to banana adapter
- High voltage test-pin
- 42 Vpk/30 Vrms rated mini Test-hook
- 600 V CAT III rated 10:1 Probe, One blue
- Probe tip to banana adapter
- High voltage test-pin
- 42 Vpk/30 Vrms rated mini Test-hook
Probe Length: 2.5m
Maximum Signal Voltage: 600 V
Maximum Voltage to Ground: 600 V rms. CAT III per IEC 1010-2-031
Attenuation: 10x
Bandwidth: 4 kHz
Input Resistance: 10 Mohm
Input Capacitance: 12.5 pF
Compensation Range: 15 to 35 pF
Note: When using the mini Test-hooks any potential must not exceed 42V pk/30 Vrms
BB120 Shielded Banana to BNC Adapter is required to adapt to ScopeMeter 120 Series shielded banana jack inputs.
Maximum Signal Voltage: 600 V
Maximum Voltage to Ground: 600 V rms. CAT III per IEC 1010-2-031
Attenuation: 10x
Bandwidth: 4 kHz
Input Resistance: 10 Mohm
Input Capacitance: 12.5 pF
Compensation Range: 15 to 35 pF
Note: When using the mini Test-hooks any potential must not exceed 42V pk/30 Vrms
BB120 Shielded Banana to BNC Adapter is required to adapt to ScopeMeter 120 Series shielded banana jack inputs.
PM8918/001 One red
PM8918/002 One red and one gray
PM8918/003 One gray
10:1 Safety Designed Probes
Probes include 600V CAT III rated 10:1 Probe, Probe tip to banana adapter, High voltage test-pin, and 42Vpk/30Vrms rated HF adapter and mini Test-hook.Probe Length: 1.5m (5 ft.)
Maximum Signal Voltage: 600Vrms CAT III , per IEC 1010-2-031
Maximum Voltage to Ground: 600Vrms CAT III , per IEC 1010-2-031
Attenuation: 10x
Bandwidth: 100MHz
Input Resistance: 10Mohm
Input Capacitance: 15pF
Compensation Range: 15 …35 pF
Note: When using the HF adapters or mini Test-hooks any potential must not exceed 42Vpk/30Vrms
BB120 Shielded Banana to BNC Adapter is required to adapt to ScopeMeter 120 Series shielded banana jack inputs.
VPS100 Voltage Probe Set 100 MHz (red & gray)
For ScopeMeter 90 Series, replaces PM8918 probe series.
Double insulated safety designed probe.
Each probe set includes 600 V CAT III / 1000 V CAT II rated
10:1 Voltage Probe (1 red, 1 gray)
Hook Clip for Probe Tip (1 red, 1 gray)
4-mm Test Probe for Probe (1 red, 1 gray)
Ground Lead with Hook Clip (1 red, 1 gray)
Ground Lead with Mini Alligator (2 black)
30V CAT II rated Ground
Spring for Probe Tip (1x)
Attenuation: 10x
Bandwidth: 100 MHz
Max. Input Voltage: 1000 V
Max. Voltage to ground: 600 V CAT III, 1000 V CAT II per IEC / EN61010-031
Input Resistance: 10 Mohm
Input Capacitance: 16 pF
Compensation range: 10 to 35 pF
Cable Length: 1.2 m
Double insulated safety designed probe.
Each probe set includes 600 V CAT III / 1000 V CAT II rated
10:1 Voltage Probe (1 red, 1 gray)
Hook Clip for Probe Tip (1 red, 1 gray)
4-mm Test Probe for Probe (1 red, 1 gray)
Ground Lead with Hook Clip (1 red, 1 gray)
Ground Lead with Mini Alligator (2 black)
30V CAT II rated Ground
Spring for Probe Tip (1x)
Attenuation: 10x
Bandwidth: 100 MHz
Max. Input Voltage: 1000 V
Max. Voltage to ground: 600 V CAT III, 1000 V CAT II per IEC / EN61010-031
Input Resistance: 10 Mohm
Input Capacitance: 16 pF
Compensation range: 10 to 35 pF
Cable Length: 1.2 m
BB120 Shielded Banana to BNC Adapter is required to adapt to ScopeMeter 120 Series shielded banana jack inputs.
VPS100-R 10:1 Voltage Probe Red 100 MHz (one red)
For ScopeMeter 90 Series, replaces PM8918 probe series.
Double insulated safety designed probe.
Probe set includes includes 600 V CAT III / 1000 V CAT II rated
10:1 Voltage Probe (1 red)
Hook Clip for Probe Tip (1 red)
4-mm Test Probe for Probe (1 red)
Ground Lead with Hook Clip (1 red)
Ground Lead with Mini Alligator (1 black)
30V CAT II rated Ground Spring for Probe Tip (1x)
Double insulated safety designed probe.
Probe set includes includes 600 V CAT III / 1000 V CAT II rated
10:1 Voltage Probe (1 red)
Hook Clip for Probe Tip (1 red)
4-mm Test Probe for Probe (1 red)
Ground Lead with Hook Clip (1 red)
Ground Lead with Mini Alligator (1 black)
30V CAT II rated Ground Spring for Probe Tip (1x)
Attenuation: 10x
Bandwidth: 100 MHz
Max. Input Voltage: 1000V
Max. Voltage to ground: 600V CAT III, 1000V CAT II per IEC / EN61010-031
Input Resistance: 10 Mohm
Input Capacitance: 16 pF
Compensation range: 10 to 35 pF
Cable Length: 1.2 m
BB120 Shielded Banana to BNC Adapter is required to adapt to ScopeMeter 120 Series shielded banana jack inputs.
Bandwidth: 100 MHz
Max. Input Voltage: 1000V
Max. Voltage to ground: 600V CAT III, 1000V CAT II per IEC / EN61010-031
Input Resistance: 10 Mohm
Input Capacitance: 16 pF
Compensation range: 10 to 35 pF
Cable Length: 1.2 m
BB120 Shielded Banana to BNC Adapter is required to adapt to ScopeMeter 120 Series shielded banana jack inputs.
PM8918/101 1:1 Probe Set Black
Obsolete. Replacement is VPS121
Includes 300V CAT III rated 1:1 Probe, Probe tip to banana adapter, High voltage test-pin, and 42Vpk/30Vrms rated mini Test-hook.
Probe Length: 1.5m (5 ft.)
Maximum Signal Voltage: 300Vrms CAT III , per IEC 1010-2-031
Maximum Voltage to Ground: 600Vrms CAT III , per IEC 1010-2-031
Attenuation: 1x
Bandwidth: 12MHz
Input Resistance: 1Mohm
Input Capacitance: <60pF
Note: When using the mini Test-hook any potential must not exceed 42Vpk/30Vrms
BB120 Shielded Banana to BNC Adapter is required to adapt to ScopeMeter 120 Series shielded banana jack inputs.
VPS121 1:1 Voltage Probe Set 12 MHz (one black)
Double insulated safety designed probe.
Each probe set includes 300 V CAT III
1:1 Voltage Probe (1 black)
Hook Clip for Probe Tip (1 red)
4-mm Test Probe for Probe (1 red)
Ground Lead with Hook Clip (1 red)
Ground Lead with Mini Alligator (1 black)
Attenuation: 1x
Bandwidth: 12 MHz
Max. Input Voltage: 300 V
Max. Voltage to ground: 600 V CAT III rated per IEC / EN61010-031
Input Resistance: 1 Mohm
Input Capacitance: 42 pF +Oscilloscope Input Capacitance
Cable Length: 1.2 m
BB120 Shielded Banana to BNC Adapter is required to adapt to ScopeMeter 120 Series shielded banana jack inputs.
PM8918/202 10:1, 2.5m. Probe Set. One red and one gray
Obsolete. Replacement is VPS250
Probes include 600V
Probe Length: 2.5m (8 ft.)
Maximum Signal Voltage: 600Vrms CAT III , per IEC 1010-2-031
Maximum Voltage to Ground: 600Vrms CAT III , per IEC 1010-2-031
Attenuation: 10x
Bandwidth: 75MHz
Input Resistance: 10Mohm
Input Capacitance: 15pF
Compensation Range: 15 …35 pF
Note: When using the HF adapters or mini Test-hooks any potential must not exceed 42Vpk/30Vrms
BB120 Shielded Banana to BNC Adapter is required to adapt to ScopeMeter 120 Series shielded banana jack inputs.
VPS250 2.5m Voltage Probe Set 75 MHz (red & gray)
Double insulated safety designed probe.
Each probe set includes
600 V CAT III / 1000V CAT II rated
10:1 Voltage Probe (1 red, 1 gray)
Hook Clip for Probe Tip (1 red, 1 gray)
4 mm Test Probe for Probe (1 red, 1 gray)
Ground Lead with Hook Clip (1 red, 1gray)
Ground Lead with Mini Alligator (2 black)
Attenuation: 10x
Bandwidth: 75 MHz
Max. Input Voltage: 1000 V
Max. Voltage to ground: 600 V CAT III, 1000 V CAT II per IEC / EN61010-031
Input Resistance: 10 MOhm
Input Capacitance: 18.5 pF
Compensation range: 10 to 35 pF
Cable Length: 2.5m
BB120 Shielded Banana to BNC Adapter is required to adapt to ScopeMeter 120 Series shielded banana jack inputs.
Each probe set includes
600 V CAT III / 1000V CAT II rated
10:1 Voltage Probe (1 red, 1 gray)
Hook Clip for Probe Tip (1 red, 1 gray)
4 mm Test Probe for Probe (1 red, 1 gray)
Ground Lead with Hook Clip (1 red, 1gray)
Ground Lead with Mini Alligator (2 black)
Attenuation: 10x
Bandwidth: 75 MHz
Max. Input Voltage: 1000 V
Max. Voltage to ground: 600 V CAT III, 1000 V CAT II per IEC / EN61010-031
Input Resistance: 10 MOhm
Input Capacitance: 18.5 pF
Compensation range: 10 to 35 pF
Cable Length: 2.5m
BB120 Shielded Banana to BNC Adapter is required to adapt to ScopeMeter 120 Series shielded banana jack inputs.
PM9084/001 Alligator clip for PM8918 Probe
Safety-designed, spring-loaded alligator clips with a 19 mm (0.75") jaw opening for use with PM 8918 safety designed probes. Set contains one red and one gray clip.
Maximum Voltage: 600V rms.CAT III , per IEC 1010-2-031
Maximum Voltage: 600V rms.
PM9085/001 Probe Hook-Style Clip for PM8918 Probe
Obsolete. Replacement is RS200
Safety-designed spring-loaded hook clip for use with PM 8918 safety designed probes.
Hook extends 10 mm x 2 mm (0.39" x 0.07").
Set contains one red and one gray clip.
Hook extends 10 mm x 2 mm (0.39" x 0.07").
Set contains one red and one gray clip.
Maximum Voltage: 600V rms. CAT III , per IEC 1010-2-031
PM9094/001 Probe accessory Set for PM8918 series probes
Set consists of:
1 Adapter Banana-BNC (PM 9081/001)
2 Probe tips to Banana Adapters, 1 red, 1 gray
2 HF Adapters, black, max voltage 30V rms.
2 Mini Testhooks, 1 red, 1 gray, max voltage 30V rms.
2 Trim Screwdrivers, 1 red, 1 gray
2 High Voltage Testpins, 1 red, 1 gray
1 Adapter Banana-BNC (PM 9081/001)
2 Probe tips to Banana Adapters, 1 red, 1 gray
2 HF Adapters, black, max voltage 30V rms.
2 Mini Testhooks, 1 red, 1 gray, max voltage 30V rms.
2 Trim Screwdrivers, 1 red, 1 gray
2 High Voltage Testpins, 1 red, 1 gray
Note: When using the mini Test-hooks any potential must not exceed 42Vpk/30Vrms
PM9095/001 Single Banana Jack to Male BNC Adapter:
Single banana to BNC adapter for direct connection 4 mm test leads to the BNC inputs of the ScopeMeter 90 Series test tool.
Set consists of one red and one gray adapter.
Maximum Signal Voltage: 300V rms. CAT III, per IEC 1010-2-031
Maximum Voltage to Ground: 600V rms. CAT III, per IEC 1010-2-031
Set consists of one red and one gray adapter.
Maximum Signal Voltage: 300V rms. CAT III, per IEC 1010-2-031
Maximum Voltage to Ground: 600V rms. CAT III, per IEC 1010-2-031
Reason.
The PM9095 was discontinued because it isn't compatible with the floating inputs of the Fluke 190 Series, and could lead to mistakes and measurement problems when used with the 190 Series. The PM9095 was designed for use with the Fluke 90-Series ScopeMeters with a common ground input. When comparing the PM9082 to the PM9095, the PM9082 adds a 'ground' banana-jack to each input, where the PM9095 required the common ground input as was implemented with the Fluke 90 Series and 105 ScopeMeters.
The PM9095 was discontinued because it isn't compatible with the floating inputs of the Fluke 190 Series, and could lead to mistakes and measurement problems when used with the 190 Series. The PM9095 was designed for use with the Fluke 90-Series ScopeMeters with a common ground input. When comparing the PM9082 to the PM9095, the PM9082 adds a 'ground' banana-jack to each input, where the PM9095 required the common ground input as was implemented with the Fluke 90 Series and 105 ScopeMeters.
PM9080/001 Optically Isolated RS232 Adapter/Cable
Safety designed serial interface for digital hard-copy output to serial printer or remote control via a PC. Compatible with Fluke ScopeMeter test tools, Power Harmonics Analyzers, Graphical MultiMeters and MultiFunction Counters.
Hard Copy: ScopeMeter test tools support Epson FX/LQ Series, LaserJet and DeskJet compatible printers.
Remote control: Waveforms, Scope and Meter measurements, Front Set-ups and performance verification/calibration.
Transfer rate: up to 57k6 Baud
Hard Copy: ScopeMeter test tools support Epson FX/LQ Series, LaserJet and DeskJet compatible printers.
Remote control: Waveforms, Scope and Meter measurements, Front Set-ups and performance verification/calibration.
Transfer rate: up to 57k6 Baud
The new cable is a temporarily solution now replaced by the final model with a different connector. The new cables are downwards compatible. Identification is possible on the optical connector
Baudrate
| |||||
PM9080 Cable
+ Instrument |
001 Old
|
101 New
|
101 Final
|
101 Cable
+ FlukeView |
101 Cable
+ Printer |
123/124/43/43B
|
19k2
|
19k2
|
19k2
|
19k2
|
19k2
|
19x
|
19k2
|
19k2
|
19k2
|
19k2
|
19k2
|
19xB / 19xC
|
19k2
|
57k6
|
57k6
|
38k4
|
19k2
|
i410 Clamp on AC/DC Current Probe 1A to 400A
Battery powered clamp on probe for basic service work with limited bandwidth.
Measures AC and DC current from 1-400A.
Measures AC and DC current down to 1A with specified accuracy and is usable to 0.5A.
Designed for industrial and commercial power distribution systems.
Enhanced safety by using double or reinforced insulation for probe jaws, handle, output cable and connector.
Input Current Range: 1A to 400A
Basic Accuracy: 3.5%
Output Signal: 1 mV/A
Output Connector: Dual Banana Plug
Frequency Range: DC to 3 kHz
Maximum Conductor Size: 30mm (1.18") diameter
Safety Rating: 600V rms. CAT III per IEC 61010-031
PM9082 Safety-Designed Dual Banana Jack to Male BNC Adapter is required to adapt to ScopeMeter 190 and 90 Series BNC inputs.
Measures AC and DC current from 1-400A.
Measures AC and DC current down to 1A with specified accuracy and is usable to 0.5A.
Designed for industrial and commercial power distribution systems.
Enhanced safety by using double or reinforced insulation for probe jaws, handle, output cable and connector.
Input Current Range: 1A to 400A
Basic Accuracy: 3.5%
Output Signal: 1 mV/A
Output Connector: Dual Banana Plug
Frequency Range: DC to 3 kHz
Maximum Conductor Size: 30mm (1.18") diameter
Safety Rating: 600V rms. CAT III per IEC 61010-031
PM9082 Safety-Designed Dual Banana Jack to Male BNC Adapter is required to adapt to ScopeMeter 190 and 90 Series BNC inputs.
80i-500s or 80i-1000s AC Current Probes
Current clamp for capturing current waveforms with Fluke ScopeMeter test tools, Fluke Power Quality Analyzer and Scopes. Enhanced safety by using double or reinforced insulation for probe jaws, handle, output cable and BNC connector (rated to 600Vrms).
Input Current Range: 1A to 500A AC rms.
Basic Accuracy: ± 2% of reading
Output Signal: 1 mV AC per 1A AC, 1000:1 division ratio
Frequency Range: 5 Hz to 10 kHz
Working Voltage: 600V AC rms.
Maximum Conductor Size: 30mm (1.18") diameter
Safety Rating: 600V rms. CAT III per IEC 61010-031
BB120 Shielded Banana to BNC Adapter is required to adapt to ScopeMeter 120 Series shielded banana jack inputs.
Basic Accuracy: ± 2% of reading
Output Signal: 1 mV AC per 1A AC, 1000:1 division ratio
Frequency Range: 5 Hz to 10 kHz
Working Voltage: 600V AC rms.
Maximum Conductor Size: 30mm (1.18") diameter
Safety Rating: 600V rms. CAT III per IEC 61010-031
BB120 Shielded Banana to BNC Adapter is required to adapt to ScopeMeter 120 Series shielded banana jack inputs.
80i-110s DC/AC Current Probe
Accurate AC, DC and AC+DC current measurements for electrical and electronic applications. Wide measurement range from 50 mA to 100A - useful to 10 mA.
2 Switch Selectable Input Ranges: 0 to 10A, 0 to 100A
Basic accuracy: ± (3% of reading + 50 mA)
Output Signal: 100 mV/A, 10 mV/A
Frequency Range: DC to 100 kHz
Working Voltage: 600V AC rms.
Maximum Conductor Size: 11.8-mm (0.46") diameter
Safety Rating: 600V rms. CAT II and 300V rms. CAT III per IEC 61010-031
BB120 Shielded Banana to BNC Adapter is required to adapt to ScopeMeter 120 Series shielded banana jack inputs.
Basic accuracy: ± (3% of reading + 50 mA)
Output Signal: 100 mV/A, 10 mV/A
Frequency Range: DC to 100 kHz
Working Voltage: 600V AC rms.
Maximum Conductor Size: 11.8-mm (0.46") diameter
Safety Rating: 600V rms. CAT II and 300V rms. CAT III per IEC 61010-031
BB120 Shielded Banana to BNC Adapter is required to adapt to ScopeMeter 120 Series shielded banana jack inputs.
80T-150U Temperature Probe
The 80T-150U is a universal temperature probe designed to provide the ScopeMeter test tools with temperature measuring capability. Intended for air, surface, and non-corrosive liquids, the probe provides direct temperature conversion of 1 mV DC per degree. A three-position switch on the unit acts as a power switch and is used for selecting Celsius or Fahrenheit scaling for the output. Operating power for the 80T-150U is derived from a standard 9 volt battery.
SPECIFICATION
Temperature Range: -50ºC to + 150ºC, or -58ºF to 320ºF, cable 70ºC maximum
Sensitivity: 1 mV per ºC or ºF
Resolution: 0.1ºC or 0.1ºF on the 200 mV range of a 3 1/2 -digit DMM
Ambient Temperature Range of Unit: 0ºC to +50ºC or 32ºF to 122ºF
Relative Humidity: 90%, non condensing from 0ºC to +35ºC
Accuracy: (including nominal 0.25% voltmeter error, in +15ºC to +35ºC ambient) ±1ºC (1.8ºF) 0ºC to 100ºC, decreasing linearly to ±3ºC (5.4ºF) at -50ºC and +150ºC
Temperature Range: -50ºC to + 150ºC, or -58ºF to 320ºF, cable 70ºC maximum
Sensitivity: 1 mV per ºC or ºF
Resolution: 0.1ºC or 0.1ºF on the 200 mV range of a 3 1/2 -digit DMM
Ambient Temperature Range of Unit: 0ºC to +50ºC or 32ºF to 122ºF
Relative Humidity: 90%, non condensing from 0ºC to +35ºC
Accuracy: (including nominal 0.25% voltmeter error, in +15ºC to +35ºC ambient) ±1ºC (1.8ºF) 0ºC to 100ºC, decreasing linearly to ±3ºC (5.4ºF) at -50ºC and +150ºC
General specification
Weight: 5.7 ounces, 161.5 grams
Overall Length: 1.36 m (53.8")
Battery: Standard 9V battery (NEDA #1604,6F22,006P)
Battery Life: 1600+ hours, typical (Alkaline Battery), 6.5V minimum
Output Termination: Standard 0.75-inch spaced double banana plug
Probe Material: Glass-filled valox
Probe Size: 15mm (0.6") maximum diameter
Tip Material: Aluminum
Tip Size: 1.8mm (0/07") to 2mm (0.08") diameter, 30% convexed
Weight: 5.7 ounces, 161.5 grams
Overall Length: 1.36 m (53.8")
Battery: Standard 9V battery (NEDA #1604,6F22,006P)
Battery Life: 1600+ hours, typical (Alkaline Battery), 6.5V minimum
Output Termination: Standard 0.75-inch spaced double banana plug
Probe Material: Glass-filled valox
Probe Size: 15mm (0.6") maximum diameter
Tip Material: Aluminum
Tip Size: 1.8mm (0/07") to 2mm (0.08") diameter, 30% convexed
80T-IR Infrared Temperature Probe
The Fluke 80T-IR Infrared Temperature Probe is a non-contact temperature measurement accessory probe which converts infrared light emitted by an object into a 1 mV DC per ºC or ºF signal. The infra-red probe has a selection switch for direct reading of temperature in ºC or ºF
Specification
Temperature Range: -18ºC to 260ºC (0ºF to 500ºF)
Accuracy: ±3% of reading or ±3ºC (±5ºF), whichever is greater, 18ºC to 28ºC (64ºF to 82ºF) ambient operating temperature
Temperature Coefficient: 0.2% of reading or ±0.2ºC (±0.3ºF), whichever is greater, change in accuracy per degree change in ambient temperature above 28ºC (82ºF) or below 18ºC (64ºF)
Response Time: 1 second
Emissivity: Fixed at .95
Output: 1 mV per ºC or ºF (Switchable)
Operating Temperature: 0ºC to 65ºC (32ºF to 150ºF)
Resolution: 1ºC or ºF
Optical Resolution: 4:1 distance to target ratio
Power: 9V Alkaline battery, included
Battery Life: 50 hours (automatic shut off after 10 minutes)
Ambient Temperature Range of Unit: 0ºC to +65ºC, or 32ºF to 150ºF
Size: (L x W x H) 180mm x 30mm x 50mm (7.1" x 1.2" x 2")
Weight: 180g (6.4 oz)
Warranty: 1 Year
Compatibility: ScopeMeter and any DMM with 10 Mohm input impedance, standard diameter banana jacks, and mV dc capability.
C95 Soft Carrying Case
Obsolete replacement C195
A soft zippered vinyl carry case (gray) designed for storing and transporting the ScopeMeter 90 Series test tool. Two separate side storage compartments are provided for test leads, probes, power adapter and other accessories. An integrated tilt stand is provided for optimum viewing angle. Not suitable for ScopeMeter 120 and 190 series
C97 Hard Carrying Case
C195 Soft Case Universal
Durable soft case.
To be used for transporting and storing the ScopeMeter test tools.
The case accommodates adjustable storage compartments suitable for all ScopeMeter models.
Storage compartments for test leads, probes, instruction manual, power adapter and other accessories.
The carrying strap allows hand or shoulder use.
Dimensions: W x H x D
50 x 20 x 25 cm
16.9 x 7.8 x 10 inches
50 x 20 x 25 cm
16.9 x 7.8 x 10 inches
Nenhum comentário:
Postar um comentário